PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
DUPLEX PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR2020
20A SP SP BRKR
THERMAL MAGNETIC, DUPLEX; 2 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR115
SP-120/240V-15A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR230
2P-120/240V-30A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR250
2P-120/240V-50A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR220
2P-120/240V-20A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
ARC FAULT CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BRCAF120
1P 20A COMB C/B
1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); APPLICATION HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; SIZE 1 INCH W; APPROVAL UL 1699, CSA; USED ON LOAD CENTER, PANEL; BR MODEL

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 Spec Sheet   |   More Details
CUTLER HAMMER VECTROL
BRCAF115
1P 15A COMB C/B

Show all:  Ground Fault Gfci Plug-In Circuit Breakers

 More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR240
2P-120/240V-40A CB
THERMAL MAGNETIC, COMMON TRIP; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
DISCONNECT SWITCH FUSED PULL-OUT
CUTLER HAMMER VECTROL
DPF221R
30A 240V 1PH PULLOUT
240 VAC 1 PHASE; 30 AMPERE; POWER RATING 10 HP; 2 WIRE; FUSIBLE FUSE; NEMA 3R; GALVANIZED STEEL ENCLOSURE; SIZE 5.4 INCH W X 3.152 INCH D X 8.7 INCH H; APPROVAL UL

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO120
SP-120/240V-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR2100
2P-120/240V-100A CB
THERMAL MAGNETIC, MAIN; 2 POLE; 208 VAC STAR/120 VAC, 240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
DUPLEX PLUG-ON CIRCUIT BREAKER
CUTLER HAMMER VECTROL
BR1515
15A SP SP BRKR
THERMAL MAGNETIC, DUPLEX; 1 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE, INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
GROUND FAULT CIRCUIT BREAKER
CUTLER HAMMER VECTROL
GFTCB120
SP-20A GRD FAULT CB
1 POLE; 120 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL

Show all:  Ground Fault Gfci Plug-In Circuit Breakers

 Spec Sheet   |   More Details
MINIATURE CIRCUIT BREAKER
SQUARE D/TELEMECANIQUE
QO2020
SP-20-20A CB
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA), 48 VDC VOLTAGE RATING; 20 AMPERE CURRENT RATING; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA), 5 KILOAMPERE AT 48 VDC; PRESSURE PLATE TERMINAL; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER), (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL, CSA; USED ON QO LOAD CENTER, NQOD PANELBOARD, OEM INTERIOR/SPEED-D[R] SWITCHBOARD DISTRIBUTION PANEL; QO[T] BRAND; QO MODEL

Show all:  Standard Trip Plug-In Circuit Breakers