Need Help? Call 805-962-9114  
   CES - SANTA BARBARA   
View Cart CART  
 Shop by Category  ( Show All )

Back

Top Sellers in Distribution Equipt - Load Centers & S. E. Equipment

   
Show  items per page    First Previous  Page   of  7  Next Last
LOAD CENTER GROUND BAR KIT
CUTLER HAMMER VECTROL
GBK10
GROUND BAR
LENGTH 4.29 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 10 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER; GBK MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
CUTLER HAMMER VECTROL
GBK14
GRND BAR
LENGTH 5.69 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 14 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
CUTLER HAMMER VECTROL
GBK21
21 CIRCUIT GROUND BAR
LENGTH 8.14 INCH; CONDUCTOR MATERIAL ALUMINUM/COPPER; 21 TERMINAL ((3) 14 TO 10 AWG OR (1) 14 TO 4 AWG); USED ON TYPE CH LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER FILLER PLATE
CUTLER HAMMER VECTROL
BRFP
FILL PLATE
CIRCUIT BREAKER SPACE; POLE SPACE 1 INCH; USED ON BR SERIES LOADCENTER

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
CUTLER HAMMER VECTROL
BR2024L125G
125A IND LDCNTR
MAIN LUG; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (20) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION C1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 21 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC; INCLUDES GROUND BAR

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
CUTLER HAMMER VECTROL
BR1224L125G
MLO 125A IND LDCNTR
MAIN LUG; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (12) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION B1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 16-3/4 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC; INCLUDES GROUND BAR

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
CUTLER HAMMER VECTROL
RH200
2-IN INTERCHANGEABLE HUB

Show all:  Load Ctrs & S. E. Equipt - Circuit Brkr Load Centers

 More Details
MAIN LUG LOAD CENTER
CUTLER HAMMER VECTROL
BR1224L125R
1PH 125A LDCTR
MAIN LUG; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); (12) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION B1R; SIZE 14-5/16 INCH W X 5-3/16 INCH D X 16-3/4 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
CUTLER HAMMER VECTROL
BR3040L200G
1PH 200A LDCTR.
MAIN LUG; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); (30) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 1 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION D1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 29-1/8 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC; INCLUDES GROUND BAR

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
CUTLER HAMMER VECTROL
RH150
1-1/2 INTERCHANGEABLE HUB

Show all:  Load Ctrs & S. E. Equipt - Circuit Brkr Load Centers

 More Details
MAIN LUG LOAD CENTER
CUTLER HAMMER VECTROL
BR612L125RP
125A CB RT LD-CNTR
MAIN LUG; 120/240 VAC; 125 AMPERE; 12 MAXIMUM CIRCUIT(S); (6) 1 INCH MAXIMUM SPACE(S); INTERRUPTING RATING 10000 AMPERE; INSULATED/BONDABLE NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 14 TO 1 AWG (ALUMINUM/COPPER); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 7R; SIZE 11 INCH W X 3-9/16 INCH D X 13 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
LOAD CENTER SPA PANEL
CUTLER HAMMER VECTROL
CH50SPAST
2P50A LDCTR SPA PANEL
MAIN BREAKER; 120/240 VAC; 50 AMPERE; CH MAIN BREAKER; BREAKER MOUNTING PLUG ON; INTERRUPTING RATING 10 KILOAMPERE; INSULATED/BONDABLE NEUTRAL; SILVER FLASH PLATED COPPER BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 14 TO 1/0 AWG (ALUMINUM/COPPER, MAIN LUG); NEMA 3R, OUTDOOR, RAIN PROOF ENCLOSURE; ENCLOSURE SIZE DESIGNATION 5R; SIZE 4.5 INCH W X 3.13 INCH D X 9.5 INCH H; APPROVAL UL; CUTLER-HAMMER[R] BRAND; CH MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER HOLD-DOWN SCREW KIT
CUTLER HAMMER VECTROL
BRHDK125
HOLD DOWN BOLT
HOLD DOWN SCREW KIT; 2 POLE; USED ON BR SERIES 150 TO 225 AMPERE CIRCUIT BREAKER; BR MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
LOAD CENTER GROUND BAR KIT
SQUARE D/TELEMECANIQUE
PK7GTA
GRNDG BAR KIT
CONDUCTOR MATERIAL ALUMINUM/COPPER; 8 TO 1 AWG; USED ON QO[R] LOADCENTER; QO[R] BRAND; PK MODEL

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
COVER SCREW
CUTLER HAMMER VECTROL
LCCS
COVER SCREWS 25PK
COVER SCREW; USED ON TYPE CH LOADCENTER AND CIRCUIT BREAKER; STANDARD PACKAGE 25; STANDARD PACKAGE 25

Show all:  Load Center Accessories

 Spec Sheet   |   More Details
* E=Each, C=100, M=1000
First Previous  Page   of  7  Next Last
 
 


233 SOUTH MILPAS STREET SANTA BARBARA, CA 93103-3607 | Tel: 805-962-9114 | Fax: 805-962-5761 | customerservice@cessb.com
Terms of Use | Terms and Conditions
3.5.4